Moment (torque) inspection of various parts The performance management of a high torque electric driver
Yes-no decision conditions etc. can save five channels.
.. A channel is only changed even if bolting conditions change. It is not necessary to reset up a maximum value and a minimum value one by one like former.
Feature:
Everyday check of an electric driver can be performed.
Since various information is displayed on a display board, it is very intelligible.
The change of a measurement unit can be performed.
Memory data is 800 affairs.
Real-time output Every about 1 / 180 seconds
The taking-in software of data can download from a homepage.
Specifications:
| Specification | DI-11 | |||
| Measuring range (at the time of Track) | 0.10~20 N・m | |||
| 1.0~200 kgf・cm | ||||
| 1.0~174 lbf・in | ||||
| Accuracy | ±0.5%(499 or less digit±3digit) | |||
| Display | The 4 figures digital display of LED | |||
| The measurement direction | CW-CCW (right and left) | |||
| Measuring mode | P-P Peak | Peak load value hold | ||
| T-R Track | Indication of real time torque value. | |||
| P-D Peak down | Holding Load Value at the moment to change from upward to downword | |||
| C(Real-time Output) | Load torque value is outputted every about 1/ 180 second. | |||
| clearance | It is a display clearance in set-up time. (0.1 – 3.0 sec) | |||
| Data output | ASCII Format (baud rate 19200) | |||
| Auto power save | 10 minutes no use, automatically switch off. | |||
| Charging time | From empty – less than 6hours | |||
| Continunous working time | 12 hours | |||
| Weight | About 1.5kg | |||
| Outside dimension | 130(W)×180(D)×34(H) | |||
| Attachment | Measurement joint SJ-50 / SJ-100 | |||
Accessories | AC/DC adaptor (Please choose AC adaptor out of 120V, and 230V.) | |||
| Exclusive receipt case | ||||
| An inspection report, a proofreading certificate, traceability system figure | ||||